86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


Perlong Medical Equipment Co., Ltd.

Showing 11 - 20 of 21, total 3 pages        [First] [Previous] [Next] [Last]

11
anesthesia unit
anesthesia unit
Specification: NDY-2B
Detail: Decompressor range£º 0.35***¡«0.40*** Flowmeter Range£º O2£º0.1¡«10L/min N2O£º0.1¡«10L/min O2-N2O interlock

12
ventilator
ventilator
Specification: PA-500
Detail: Ventilation Capacity per Minute£º ¡Ý18L Oxygen Concentration£º <45% Ventilator Conformance£º ¡Ü30mL/kpa Respiratory Rate£º 6¡«60/m I/E Ratio:£º 1£º1.5£¬1£º2.0£¬1£º2.5£¬1£º3.0 Maximum Safe Pressure£º ¡Ü6.0kPa ( Ptr)...

13
multifunctional anesthesia unit
multifunctional anesthesia unit
Specification: JINLING-1B
Detail: Oxygen Supply Speed£º 35¡«75L/min Ventilator£º Humidity Volume£º 100¡«1200mL/p Airway Pressure Indication£º -1¡«7.0kpa£¨¡À5%£© Airway Pressure Range£º 1¡«7kPa Respiratory Rate£º 8¡«40/m I:E Ratio£º 1:1.0¡«1:3.0 ...

14
multifunctional anesthesia unit
multifunctional anesthesia unit
Specification: JINLING-01
Detail: Oxygen Supply Speed£º 35¡«75L/min Ventilator£º Tidal Volume£º 50¡«1200mL/p Respiratory Rate£º 6¡«80/m I/E Ratio£º 1£º0.5¡«1£º3.0 Airway Pressure Indication£º 0¡«10kPa Airway Pressure Range£º 0¡«10kPa

15
two- channel blood coagulation analyzer
two- channel blood coagulation analyzer
Specification: PUN-2048B
Detail: Reagent Storage£º 4 Sample Preparation Positions£º 6, 3 with timer Reagent Volume£º 100¦Ìl Stray£º ¡Ü1% Interchannel Error£º ¡Ü3% Linearity Error£º ¡Ü1%

16
biochemistry analyzer
biochemistry analyzer
Specification: PUS-2018
Detail: Measurement Range£º 0.001¡«3.000Abs Precision£º ¡À0.001Abs Repeatability£º ¡Ü0.005Abs Linearity£º ¡Ü¡À1% Cross-contamination £º ¡Ü1% Temperature Accuracy£º ¡À0.1¡æ Test Temperature£º 25¡æ¡¢30¡æ¡¢37¡æ Test Method...

17
pcr thermal cycler
pcr thermal cycler
Specification: PUK-2028
Detail: Ramping Speed£º 0¡«999 Number of Repeat Cycles£º 0¡«999 Tank Volume£º 500ml Temperature Accuracy£º ¡À0.3¡æ Temperature Balance£º ¡Ü0.5¡æ Temperature Stability £º ¡Ü0.5¡æ/h Heating and Cooling Ramp Rate 0.5ml Block ...

18
microplate washer
microplate washer
Specification: DNX-9620
Detail: Applicable Microplate£º 96 , 48 or 32 wells microplate Washing Times Option£º 1¡«9,can be preset Washing Rows Option£º 1¡«12, can be preset Soak Time£º 1¡«3600s Residual Volume£º £¼3¦Ìl/well

19
microplate reader
microplate reader
Specification: DNM-9602G
Detail: Measurement Range£º 0.000-4.000Abs Photometric Accuracy£º ¡À1% or ¡À0.001Abs Repeatability£º £¼¡À0.3% Stability£º £¼0.002Abs Linearity£º £¼¡À0.5% Reading Speed£º £¼5secs/96holes£¨single wavelength£© £¼7secs/96holes...

20
microplate reader
microplate reader
Specification: DNM-9602A
Detail: Measurement Range£º 0.001¡ª3.500Abs Photometric Accuracy£º ¡À1% or ¡À0.001Abs Repeatability£º £¼¡À0.5% Stability£º £¼0.005Abs Linearity£º £¼¡À1% Reading Speed£º £¼5secs/96holes£¨single wavelength£© £¼7secs/96holes£¨...
Showing 11 - 20 of 21, total 3 pages        [First] [Previous] [Next] [Last]
1 2 3


Copyright© Perlong Medical Equipment Co., Ltd. All Rights Reserved.
Tel : 86 25 52635350 9009 Fax : 86 25 52635356
Powered by 86exporter.com