Perlong Medical Equipment Co., Ltd.

Products >> Patient Monitor

Patient Monitor

Build Your Online Product Catalogs?



Description
Product Name: Patient Monitor
Supply Ability:
Related proudcts
Specifications PDJ-3000
Price Term: FOB,CNF
Port of loading: Nanjing, shanghai
Minimum Order 1 unit
Unit Price:

Work condition
Power supply£º AC 220V¡À22V ¡¢50HZ
Performance
Display£º 12¡åcolor TFT display to show 4 ¡« 9 waveforms
Resolution£º 640¡Á480 pixels
Tend observation£º Tend chart of 1 ¨C 72 hours
Alarm£º upper and lower limit alarm, audible and visual
Net working£º Can be connected to central monitor and long-distance monitor
Memory module£º build-in thermal array recorders
ECG
Leadt£º 5 leads£ºRA£»LA£»RL£»LL£»V
Lead Selection£º ¢ñ£»¢ò£»¢ó£»avR£»avL£»avF£»V£»MCL1
Waveforms£º 7 channels
Gain£º ¡Á0.5, ¡Á1, ¡Á2, ¡Á4
Heart rate & alarm
Measuring range£º Adult: 20¡«250 bpm
Neonate/pediatric: 20¡«250bpm
Accuracy£º ¡À2% or 2 bpm
Sensibility£º >200¦ÌV (peak value)
Input impedance£º >5M¦¸
Common mode rejection ratio£º > 85dB
Current leakage£º <30¦ÌA
ECG signal range£º ¡À10mV (peak value)
Voltage range of electrode polarization£º ¡À300mV
Bandwidth£º Operation mode: 1¡«25Hz
Monitor mode: 0.5¡«35Hz
Diagnosis mode: 0.05¡«100Hz
ST segment monitor£º yes, -1.0Mv ¡« 1.0 mV
Work mode£º diagnosis, monitor, and surgery
Respiration
Measuring range£º Adults: 1¡«99bpm
Neonate/pediatric: 1¡«99bpm
Measuring method£º RA-LL Impedance
Accuracy£º ¡À2bpm or ¡À10%
Differential input impedance£º >2.5M¦¸
Resolution£º 1bpm
Non-invasive blood pressure(NIBP)
Measuring method £º automatic vibration
Work mode£º automatic/manual
Pulse rate range£º 0¡«255bpm
Unit£º mmHg or kPa
Over pressure safety£º Adult mode: 300mmHg
Pediatric mode: 180mmHg
Neonate mode: 120mmHg
Alarm range£º SYST: 50¡«240mmHg
DIAS: 30¡«180mmHg
MEAN: 25¡«200mmHg
Measuring range£º SYST: 50¡«240mmHg
DIAS: 30¡«180mmHg
MEAN: 25¡«200mmHg
Resolution£º 1mmHg
Accuracy£º Max mean error: ¡À5mmHg or ¡À5%
SpO2
Measuring range£º 0¡«100%
Accuracy£º 80¡«100% ¡À2%, 60¡«79% ¡À3%, £¼ 60% Ignore
Refresh time£º 1s
Alarm range£º Sustained adjustment of upper and lower limit between 1¡«100%
Alarm delayed time£º 10s
Pulse Rate
Pulse rate range£º 0¡«254bpm
Resolution£º 1bpm
Accuracy£º ¡À1

Contact Us
Company: Perlong Medical Equipment Co., Ltd.
Contact: Ms. wendy shi
Address: wendyshj@hotmail.com
Postcode: 210007
Tel: 86 25 52635350 9009
Fax: 86 25 52635356
E-mail:         


Copyright© Perlong Medical Equipment Co., Ltd. All Rights Reserved.
Tel : 86 25 52635350 9009 Fax : 86 25 52635356
Powered by 86exporter.com